图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: DRP024V060W1AA
  • 制造商: DELTA PRODUCTS CORPORATION
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

DRP024V060W1AA产品简介:

ICGOO电子元器件商城为您提供DRP024V060W1AA由DELTA PRODUCTS CORPORATION设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 DRP024V060W1AA价格参考。DELTA PRODUCTS CORPORATIONDRP024V060W1AA封装/规格:AC DC 转换器, 封闭式,保形涂层 AC DC 转换器 1 输出 24V 2.5A 85 ~ 264 VAC 输入。您可以下载DRP024V060W1AA参考资料、Datasheet数据手册功能说明书,资料中有DRP024V060W1AA 详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
2D图纸

http://www.deltapsu.com/upload/product_image/17_20130401_001613682_DRP024V060W1AA.dxf.zip

3D型号

http://www.deltapsu.com/upload/product_image/17_17_20130401_001613682_DRP024V060W1AA%20(EOE11010006)%203D%20Rev.%2000.stp.zip

产品目录

电源 - 外部/内部(外接)

描述

POWER SUPPLY DIN RAIL 60W 24VDC

产品分类

AC DC 转换器

品牌

Delta Electronics

数据手册

点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet

产品图片

产品型号

DRP024V060W1AA

rohs

无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

CliQ

产品培训模块

http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=30014

产品目录页面

点击此处下载产品Datasheet

其它名称

603-1226
EOE11010006

其它有关文件

点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet点击此处下载产品Datasheet

功率(W)

60W

功率(W)-最大值

60W

大小/尺寸

4.76" 长 x 1.26" 宽 x 4.72" 高(121.0mm x 32.0mm x 120.0mm)

安装类型

DIN 轨道

工作温度

-20°C ~ 75°C

应用

ITE (Commercial)

所需最小负载

-

效率

87%

标准包装

1

特性

可调输出,DC 输入能力,负载均分,通用输入

特色产品

http://www.digikey.com/cn/zh/ph/Delta/DVPseries.htmlhttp://www.digikey.cn/product-highlights/cn/zh/delta-power-mgmt-acdc-industrial/3751

电压-输入

85 ~ 264 VAC

电压-输出1

24V

电压-输出2

-

电压-输出3

-

电压-输出4

-

电压-隔离

4kV(4000V)

电流-输出(最大值)

2.5A

类型

封闭式

认可

cCSAus, CE, cULus, cURus

输出数

1

推荐商品

型号:PSC-60A

品牌:MEAN WELL USA Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:VMS-60-48

品牌:CUI Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:NES-100-9

品牌:MEAN WELL USA Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:HRPG-300-12

品牌:MEAN WELL USA Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:MDS-040APS12 BA

品牌:Delta Electronics

产品名称:电源 - 外部/内部(外接)

获取报价

型号:SWS300A4/CO2

品牌:TDK-Lambda Americas Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:SWS15012/CO2

品牌:TDK-Lambda Americas Inc.

产品名称:电源 - 外部/内部(外接)

获取报价

型号:SPN100-15S

品牌:Kaga Electronics USA

产品名称:电源 - 外部/内部(外接)

获取报价

样品试用

万种样品免费试用

去申请
DRP024V060W1AA 相关产品

MSM8015F

品牌:Inventus Power

价格:

RACM100-24S

品牌:Recom Power

价格:¥582.72-¥582.72

PBA300F-48-F3

品牌:Cosel USA, Inc.

价格:

FPS100048/PS

品牌:TDK-Lambda Americas Inc.

价格:

ESP-120-27

品牌:MEAN WELL USA Inc.

价格:¥435.67-¥489.06

ZWS150AF48

品牌:TDK-Lambda Americas Inc.

价格:

HFE1600-24/S

品牌:TDK-Lambda Americas Inc.

价格:

LEA75F-15-SN

品牌:Cosel USA, Inc.

价格:

PDF Datasheet 数据手册内容提取

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Highlights & Features  Universal AC input voltage  Power will not de-rate for the entire input voltage range  Power Boost of 150% for 3 seconds  Full corrosion resistant aluminium chassis  SEMI F47 certified  Hazardous Locations approval to ATEX and Class I, Div 2 Safety Standards CB Certified for worldwide use Model Number: DRP024V060W1AA Unit Weight: 0.37 kg (0.82 lb) Dimensions (L x W x D): 121 x 32 x 120 mm (4.76 x 1.26 x 4.72 inch) General Description The DRP024V060W1AA is part of the CliQ DIN rail power supply series from one of the world’s leading power supply companies, Delta Electronics Group. The rugged metal has a compact body at only 32mm, which is both shock and vibration resistant according to IEC 60068-2 standard. The product operates within a wide temperature range from -20°C to +80°C. The DRP024V060W1AA features universal AC input voltage range from 85Vac to 264Vac and the power will not de-rate for the entire input voltage range. The single phase power supply unit includes overvoltage, overcurrent, over temperature and short circuit protections. The product features built-in Power Boost of 150% for 3 seconds. Such feature enables reserve power to be always available for reliable startup of loads with high inrush current, thus eliminating the need of a more expensive power supply unit at higher power rating. Another great feature is the conformal coating on the PCBA which allows DRP024V060W1AA to be certified to ATEX and Class I, Div 2 for use in hazardous locations. Model Information CliQ DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP024V060W1AA 85-264Vac (120-375Vdc) 24Vdc 2.50A Model Numbering DR P 024V 060W 1 A A DIN Rail Power Supply Output Voltage Output Power Single Phase CliQ Series Metal Case All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz DC Input Voltage Range* 120-375Vdc Input Current < 1.10A @ 115Vac, < 0.70A @ 230Vac Efficiency at 100% Load > 86.0% @ 115Vac, > 87.0% @ 230Vac Max Inrush Current (Cold Start) < 40A @ 115Vac, < 80A @ 230Vac Leakage Current < 1mA @ 240Vac *Safety approval according to IEC/EN/UL 60950-1. Output Ratings / Characteristics Nominal Output Voltage 24Vdc Output Voltage Tolerance ± 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 22-28Vdc Output Current 2.50A (continuously operating at 24) 3.75A (Power Boost for 3 seconds at 24V, refer to the details in the Functions section) Output Power 60W (continuously operating at 24V) 90W (Power Boost for 3 seconds at 24V, refer to the details in the Functions section) Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% load) Load Regulation < 1% typ. (@ 85-264Vac input, 0-100% load) PARD (20MHz) < 240mVpp Rise Time < 100ms @ nominal input (100% load) Start-up Time < 3,000ms @ nominal input (100% load) Hold-up Time > 20ms @ 115Vac, > 125ms @ 230Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 10-100% load Start-up with Capacitive Loads 8,000µF Max All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 2 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Mechanical Case Cover / Chassis Aluminium Dimensions (L x W x D) 121 x 32 x 120 mm (4.76 x 1.26 x 4.72 inch) Unit Weight 0.37 kg (0.82 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal Input 3 Pins (Rated 300V/20A) Output 2 Pins (Rated 300V/20A) Wire AWG 22-14 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 40dBA Environment Surrounding Air Temperature Operating -20°C to +80°C Storage -25°C to +85°C Power De-rating Vertical Mounting < 0°C de-rate power by 1% / °C, > 50°C de-rate power by 2.5% / °C Horizontal Mounting < 0°C de-rate power by 1% / °C, > 50°C de-rate power by 2.5% / °C > 70°C de-rate power by 4% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,000 Meters (6,560 ft) (@ 50°C) Shock Test (Non-Operating) IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 3 times per direction, 18 times in total Vibration (Non-Operating) IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage 32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent > 150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection *PE: Primary Earth Reliability Data MTBF > 500,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 3 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Safety Standards / Directives Electrical Equipment in Power Installations EN 50178 / IEC 62103 Electrical Safety SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (under alternate part number EOE11010006 of File No. E191395), CSA to CSA C22.2 No. 60950-1 and UL 60950-1, CB scheme to IEC 60950-1 Industrial Control Equipment UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (under alternate part number EOE11010006 of File No. E315355), CSA to CSA C22.2 No. 107.1-01 (under alternate part number EOE11010006 of File No. 181564) Hazardous Location / ATEX cCSAus to CSA C22.2 No. 213-M1987and ANSI / ISA 12.12.01:2007 Class I, Division 2, Group A, B, C, D T4, Ta= -20°C to +80°C (> +50°C derating) EN 60079-0:2009, EN 60079-15:2010 ( II 3G Ex nA IIC T4 Gc, Ta= -20°C to +80°C (> +50°C derating)) II 3G ATEX 94/9/EC; Certificate No. EPS 09 ATEX 1 215 X; IECEx test report For IEC 60079-0, IEC 60079-15 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 4.0KVac Input to Ground 1.5KVac Output to Ground 1.5KVac All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 4 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA EMC EMC / Emissions CISPR 32, EN 55032, EN 55011, FCC Title 47: Class B Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M, 80% modulation (1kHz) Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 2kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 1A/Meter Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1Kv Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Voltage Sag Immunity SEMI F47 - 0706, at 110Vac 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 5 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Block Diagram Device Description 1) Input terminal block connector 2) Output terminal block connector 3) DC Voltage adjustment potentiometer 4) DC OK control LED (Green) 5) Universal mounting rail system All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 6 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Dimensions L x W x D: 121 x 32 x 120 mm (4.76 x 1.26 x 4.72 inch) Engineering Data Output Load De-rating VS Surrounding Air Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature > 50°C, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) with adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power Fig. 1 De-rating for Vertical Mounting Orientation supply, the device can be very hot! < 0°C de-rate power by 1% / °C, 5. If the device has to be mounted in any other > 50°C de-rate power by 2.5% / °C orientation, please do not hesitate to contact info@deltapsu.com for more details. De-rating for Horizontal Mounting Orientation < 0°C de-rate power by 1% / °C, > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 7 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Output Load De-rating VS. Input Voltage  No output power de-rating across the entire input voltage range ■L Frame / Enclosed Assembly & Installation The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. The device should be installed with input terminal block at the bottom. Each device is delivered ready to install. Mounting Dismounting Fig. 2.1 Mounting Fig. 2.2 Dismounting Snap on the DIN rail as shown in Fig. 2.1: To uninstall, pull or slide down the latch with screw driver as 1. Tilt the unit upwards and insert it onto the DIN rail. shown in Fig. 2.2. Then slide the power supply unit (PSU) in the 2. Push downwards until stopped. opposite direction, release the latch and pull out the power 3. Press against the bottom front side for locking. supply unit (PSU) from the rail. 4. Shake the unit slightly to ensure that it is secured. In accordance to EN 60950 / UL 50950, flexible cables require ferrules. Use appropriate copper cables designed to sustain operating temperature of at least 75°C or more to fulfill UL requirements. For stranded wires it is recommended to use suitable lug to crimp wires. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 8 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Safety Instructions  Vertical Mounting  Horizontal Mounting  ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage.  To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units.  Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns!  Only plug in and unplug connectors when power is turned off!  DO NOT insert any objects into the unit.  Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time.  The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must comply with EN 60079-0 or EN 60079-15.  CAUTION: “For use in a controlled environment”.  Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.  Warning: Explosion Hazard - Do not disconnect equipment unless the power has been switched off or the area is known to be non-hazardous. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 9 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Functions Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 90% of its set value, after the input voltage is removed. Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured The power supply output voltage will remains within ±5% of its and, occurs when the input voltage is first applied. For AC input steady state value, when subjected to a dynamic load from 10 to voltages, the maximum peak value of inrush current will occur 100% of its rated current. during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 10 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Power Boost Power Boost is the reserve power available constantly that allows relia ble startup to support s udden and short spike of loads with high inrush c urrent typically during turn on to remove the need o f more expensive higher rated power supply unit. A fter the output has reached its steady state set v alue, the power supply can support surge loads w ith a higher short-term power demand up to 150% o f maximum rated load (IO Max), for a maximum d uration of 3 seconds. The Power Boost is also a vailable to repeatedly basis with according to the c ondition of an average (R.M.S) output power shall n ot exceed continuous operating condition or refer t o duty cycle calculation below. 𝑇 𝐷𝑢𝑡𝑦 𝑐𝑦𝑐𝑙𝑒 (%)= 𝑃 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 (𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 ×𝑇 )+(𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟×𝑇 ) 𝑃 𝑁 𝐴𝑣𝑒𝑟𝑎𝑔𝑒 𝑂𝑢𝑡𝑝𝑢𝑡 𝑃𝑜𝑤𝑒𝑟 (𝑃 )= 𝐴𝑣𝑔 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 OR (𝑃 ×𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒)−(𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 ×𝑇 ) 𝐴𝑣𝑔 𝑃 𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟 = 𝑇 𝑁  An example of Power Boost and Average Output Power Peak Power Power Boost Non-Peak Non-Peak Power Total Time Power Boost Duty Cycle (WP) Duration (TP) Power (WN) Duration (TN) (T) 150% 90 3 sec 10% 57W 27 sec 30 sec 150% 90 3 sec 35% 44W 5.5 sec 8.5 sec 120% 72 6 sec 20% 57W 24 sec 30 sec 120% 72 6 sec 35% 53W 11 sec 17 sec It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause damage to the PSU. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 11 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Overload & Overcurrent Protections Overvoltage Protection The power supply’s Overload (OLP) and Overcurrent (OCP) The power supply’s overvoltage circuit will be activated when its Protections will be activated when output current exceeds 150% of internal feedback circuit fails. The output voltage shall not exceed IO (Max load). In such occurrence, the VO will start to droop and its specifications defined on Page 3 under “Protections”. The power once the power supply has reached its maximum power limit, the supply doesn’t shut down but goes in 2nd level regulation at 30- protection is activated and the power supply will go into “Hiccup 32Vdc and continue to deliver the power. According to high output mode” (Auto-Recovery). The power supply will recover once the voltage which will be operating > 100% of rated load (32V × rated fault condition of the OLP and OCP is removed and IO is back within output current), if this condition persists, the power supply will the specifications. sense OTP (Over Temperature Protection) and will go under hiccup mode. The power will return to normal operation once the fault condition is removed. It is not recommended to prolong the duration of IO when it is <150% but >100%, since it may cause damage to the PSU. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Short Circuit Protection Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating The power supply’s output OLP/OCP function also provides temperature is beyond what is recommended in the de-rating protection against short circuits. When a short circuit is applied, the graph. When activated, the output voltage will go into bouncing output current will operate in “Hiccup mode”, as shown in the mode until the temperature drops to its normal operating illustration in the OLP/OCP section on this page. The power supply temperature as recommended in the de-rating graph. will return to normal operation after the short circuit is removed. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 12 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Operating Mode Fig. 3 Redundancy / Parallel Operation Connection Diagram  Redundancy Operation In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference between the two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the right DRR module, 20A as per the system requirement to the power supply units PSU 1 and PSU 2 at Vin 1 & Vin 2 respectively. Step 3. Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module).  Parallel Operation These DRR modules can also be used for Parallel function in order to increase the output power by N+1 (e.g. 2.5A + 2.5A = 5A or 2.5A + 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the DRP024V060W1AA is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (Refer to Fig. 3 for the Connection Diagram). Step 1. Step 3. Set output load condition for both supplies at 50% and measure Connect PSU 1 and PSU 2 with the DRR-20A module and the output voltages. measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure the voltages are within ±25mV. Step 2. Adjust output voltages to the same level or within ±25mV Step 4. difference. Output voltage from DRR module Vout will be = VO (output voltage of power supply) – Vdrop* (in DRR module). *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 13 www.DeltaPSU.com (November 2018, Rev. 07)

T ECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AA Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. Conformal Coating The Protective Coating Technology Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere. Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 14 www.DeltaPSU.com (November 2018, Rev. 07)

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: D elta Electronics: DRP024V060W1AA