图片仅供参考

详细数据请看参考数据手册

Datasheet下载
  • 型号: HIH-5031-001S
  • 制造商: Honeywell Solid State Electronics
  • 库位|库存: xxxx|xxxx
  • 要求:
数量阶梯 香港交货 国内含税
+xxxx $xxxx ¥xxxx

查看当月历史价格

查看今年历史价格

HIH-5031-001S产品简介:

ICGOO电子元器件商城为您提供HIH-5031-001S由Honeywell Solid State Electronics设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 HIH-5031-001S价格参考¥252.85-¥313.79。Honeywell Solid State ElectronicsHIH-5031-001S封装/规格:湿度,湿敏传感器, Humidity Temperature Sensor 0 ~ 100% RH Analog Voltage ±3% RH 5s Surface Mount。您可以下载HIH-5031-001S参考资料、Datasheet数据手册功能说明书,资料中有HIH-5031-001S 详细功能的应用电路图电压和使用方法及教程。

产品参数 图文手册 常见问题
参数 数值
产品目录

传感器,变送器

描述

SENSOR HUMIDITY 5.5V 3% SMD板上安装湿度传感器 HyCal Sensing Produc 3600 Series CMOS Sen

产品分类

湿度传感器,湿度环境传感器

品牌

Honeywell

产品手册

点击此处下载产品Datasheet

产品图片

rohs

过渡期间无铅 / 符合限制有害物质指令(RoHS)规范要求

产品系列

板上安装湿度传感器,Honeywell HIH-5031-001S-

数据手册

http://sensing.honeywell.com/index.php/ci_id/49692/la_id/1/document/1/re_id/0http://sensing.honeywell.com/index.php/ci_id/49693/la_id/1/document/1/re_id/0

产品型号

HIH-5031-001S

RH精度

3 %

RH范围

0 % to 100 %

产品

Board Mount

产品培训模块

http://www.digikey.cn/PTM/IndividualPTM.page?site=cn&lang=zhs&ptm=24912

产品种类

板上安装湿度传感器

传感器类型

电容性

其它名称

480-4967
HIH-5031-001S-ND
HIH5031001S

响应时间

5s

商标

Honeywell

商标名

HumidIcon

安装风格

SMD/SMT

工作温度

-40°C ~ 85°C

描述/功能

Filtered, 5 Piece Sample Pack

最大工作温度

+ 85 C

最小工作温度

- 40 C

标准包装

1

湿度范围

0 ~ 100% 相对湿度

灵敏度

-

电压-电源

2.7 V ~ 5.5 V

电容

-

电源电压-最大

5.5 V

电源电压-最小

2.7 V

电源电流

200 uA

精度

±3% RH

输出

线性电压

输出类型

Analog

推荐商品

型号:HIH-4000-004

品牌:Honeywell Sensing and Productivity Solutions

产品名称:传感器,变送器

获取报价

型号:HDC1000YPAT

品牌:Texas Instruments

产品名称:传感器,变送器

获取报价

型号:CHS-MSS

品牌:TDK Corporation

产品名称:传感器,变送器

获取报价

型号:SHT30-ARP-B

品牌:Sensirion AG

产品名称:传感器,变送器

获取报价

型号:CC2D23

品牌:Amphenol Advanced Sensors

产品名称:传感器,变送器

获取报价

型号:CC2D35S

品牌:Amphenol Advanced Sensors

产品名称:传感器,变送器

获取报价

型号:SHT21S

品牌:Sensirion AG

产品名称:传感器,变送器

获取报价

型号:HIH-5031-001

品牌:Honeywell Sensing and Productivity Solutions

产品名称:传感器,变送器

获取报价

样品试用

万种样品免费试用

去申请
HIH-5031-001S 相关产品

HIH-4000-001

品牌:Honeywell Sensing and Productivity Solutions

价格:¥151.12-¥160.27

CHS-UPS

品牌:TDK Corporation

价格:

HIH8130-021-001

品牌:Honeywell Sensing and Productivity Solutions

价格:

HIH6130-021-001

品牌:Honeywell Sensing and Productivity Solutions

价格:¥71.97-¥122.97

HIH6121-021-001

品牌:Honeywell Sensing and Productivity Solutions

价格:¥81.72-¥139.54

HIH6130-021-001S

品牌:Honeywell Sensing and Productivity Solutions

价格:¥471.89-¥499.80

HIH6021-021-001S

品牌:Honeywell Sensing and Productivity Solutions

价格:

CC2D23-SIP

品牌:Amphenol Advanced Sensors

价格:¥65.45-¥69.39

PDF Datasheet 数据手册内容提取

DESCRIPTION The HIH-5030/5031 Series Low Voltage Humidity Sensors The HIH-5030/5031 Series delivers instrumentation-quality RH operate down to 2.7 Vdc, often ideal in battery-powered (Relative Humidity) sensing performance in a competitively systems where the supply is a nominal 3 Vdc. priced, solderable SMD. The HIH 5030/5031 complements our existing line of 5 Vdc The HIH-5030 is a covered integrated circuit humidity sensor. SMD (Surface Mount Device) humidity sensors. SMD The HIH-5031 is a covered, condensation-resistant, integrated packaging on tape and reel allows for use in high volume, circuit humidity sensor that is factory-fitted with a hydrophobic automated pick and place manufacturing, eliminating lead filter allowing it to be used in many condensing environments misalignment to printed circuit board through-holes. including industrial, medical and commercial applications. The HIH-5030/5031 Series Humidity Sensors are designed The RH sensor uses a laser trimmed, thermoset polymer specifically for high volume OEM (Original Equipment capacitive sensing element with on-chip integrated signal Manufacturer) users. conditioning. Direct input to a controller or other device is made possible by The sensing element's multilayer construction provides this sensors near linear voltage output. With a typical current excellent resistance to most application hazards such as draw of only 200 A, the HIH-5030/5031 Series is ideally condensation, dust, dirt, oils and common environmental suited for many low drain, battery operated systems. chemicals. Tight sensor interchangeability reduces or eliminates OEM Sample packs are available. See order guide. production calibration costs. FEATURES POTENTIAL APPLICATIONS Operates down to 2.7 Vdc, often ideal in battery-powered Industrial systems where the supply is a nominal 3 Vdc. Air compressors Tape and reel packaging allows for use in high volume pick Battery-powered systems and place manufacturing (1,000 units per tape and reel) Drying equipment Molded thermoset plastic housing HVAC (includes air conditioning, air movement, Near linear voltage output vs %RH thermostats, humidifiers, de-humidifiers, humidistats, Laser trimmed interchangeability enthalpy sensing) Low power design OEM assemblies Enhanced accuracy Office automation equipment Fast response time Process equipment Stable, low drift performance Refrigeration (includes bulk and transport systems) Chemically resistant Telecommunications cabinets Weather stations and meteorology equipment Medical Hospital air compressors Infant incubators Microenvironments Sleep apnea equipment Treadmill stress monitoring equipment

Table 1. Performance Specifications (At 3.3 Vdc supply and 25 C [77 F] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note Interchangeability (first order curve) 0% RH to 10% RH, 90% RH to 100% RH -7 7 % RH 11% RH to 89% RH -3 3 % RH Accuracy (best fit straight line) 11% RH to 89% RH -3 +3 % RH 4 Hysteresis 2 % RH Repeatability 0.5 % RH Settling time 70 ms Response time (1/e in slow moving air) 5 s Stability (at 50% RH in 5 years) 1.2 % RH 1 Voltage supply 2.7 5.5 Vdc 2 Current supply 200 500 A Voltage output (1st order curve fit) V =(V )(0.00636(sensor RH) + 0.1515), typical at 25 C OUT SUPPLY Temperature compensation True RH = (Sensor RH)/(1.0546 0.00216T), T in C Output voltage temp. coefficient at 50% RH, 3.3 V -2 mV/ C Operating temperature -40[-40] See Figure 2. 85[185] C[ F] Operating humidity (HIH-5030) 0 See Figure 2. 100 % RH 3 Operating humidity (HIH-5031) 0 See Figure 2. 100 % RH Storage temperature -50[-58] 125[257] C [ F] Storage humidity See Figure 3. % RH 3 Specific Notes: General Notes: 1. Includes stress outside of recommended operating zone. Sensor is ratiometric to supply voltage. 2. Device is tested at 3.3 Vdc and 25 C. Extended exposure to >90 % RH causes a reversible shift 3. Non-condensing environment. When liquid water falls on of 3 % RH. the humidity sensor die, output goes to a low rail condition Sensor is light sensitive. For best performance, shield indicating no humidity. sensor from bright light. 4. Total accuracy including interchangeability is 3 %RH. 2 www.honeywell.com/sensing

Figure 1. Operating Environment (Non-condensing environment for HIH-5030 catalog listings only.) 100% 90% 80% 70% y t di mi 60% u H 50% e v ti 40% a el R 30% 20% 10% 0% -40 -20 0 20 40 60 80 100 Recommended operating zone Temperature ºC Operating zone limited to <50 hours No specification zone Figure 2. Storage Environment (Non-condensing environment for HIH-5030 catalog listings only.) 100% 90% 80% 70% y t di mi 60% u H 50% e v ti 40% a el R 30% 20% 10% 0% -40 -20 0 20 40 60 80 100 120 140 Recommended storage zone Temperature ºC Honeywell Sensing and Control 3

Figure 3. Typical Output Voltage vs Relative Humidity (At 25 °C and 3.3 Vdc.) 3 2.5 ) c d V 2 ( e Rising RH g ta 1.5 Falling RH ol V t u p 1 t u O 0.5 0 20 40 60 80 100 Relative Humidity (%RH) Figure 4. Typical Output Voltage (BFSL) vs Relative Humidity (At 0 C, 70 C and 3.3 Vdc.) 3 2.5 ) c d V 2 ( e 70° C g a t 1.5 0° C ol V t u p 1 t u O 0.5 0 20 40 60 80 100 Relative Humidity (%RH) 4 www.honeywell.com/sensing

Figure 5. HIH-5030 Mounting Dimensions (For reference only. mm/[in]) 4,17 ±0,05 [0.164 ±0.002] 1,78 [0.070] 2,27 ±0,05 2,67 [0.090 ±0.002] [0.105] 0,71 [0.028] 0,41 [0.016] 8,59 ±0,05 [0.338 ±0.002] 0.57 [0.226] 1,22 [0.048] -ve +ve 2,54 [0.100] OUT 2,62 [0.103] 2,95 3X 0,38 [0.116] 1,27 [0.015] [0.050] 2,54 [0.100] Figure 6. HIH-5030 PCB Landing Pattern (For rePfeCreBn cLeA oNnDly.I NmGm /P[inA])T TERN 2,54 [0.10] 2,29 [0.09] 8,89 [0.35] 2X 1,27 [0.05] 3X 0,51 [0.02] 1,78 [0.07] Honeywell Sensing and Control 5

Figure 7. HIH-5031 Mounting Dimensions (For reference only. mm/[in]) 4,17 ±0,05 [0.164 ±0.002] 1,78 [0.070] 2,27 ±0,05 2,67 [0.090 ±0.002] [0.105] 0,71 [0.028] 0,41 8,59 ±0,05 [0.016] [0.338 ±0.002] 0.57 [0.226] 1,22 FILTER [0.048] -ve +ve 2,54 [0.100] OUT 2,62 [0.103] 2,95 3X 0,38 [0.116] 1,27 [0.015] [0.050] 2,54 [0.100] Figure 8. HIH-5031 PCB Landing Pattern (For rePfeCreBn cLeA oNnDly.I NmGm /P[inA])T TERN 2,54 [0.10] 2,29 [0.09] 8,89 [0.35] 2X 1,27 [0.05] 3X 0,51 [0.02] 1,78 [0.07] 6 www.honeywell.com/sensing

Figure 9. Tape and Reel Dimensions (For reference only. mm/[in]) 3,99 [0.157] DIA. 1,50 1,75 3,91 [02.0,0719] [0.059] [0.069] [0.154] 25,4 [1] 2,64 [0.104] 11,51 [0.453] 24,00 [02.0,6746] [0.945] D I A . 1 0[41],6 D I A . 3 [3103,]2 22,25 [0.876] DIA. 1,50 [0.059] 8,00 [0.315] 0,343 [0.0135] Figure 10. Typical Application Circuit + Ve Supply Voltage (3.3 V) HIH-50XX OUT Voltage Out - Ve 65 Minimum kOhm Load 0 V ORDER GUIDE Catalog Listing Description HIH-5030-001 Covered integrated circuit humidity sensor, SMD, 1000 units on tape and reel HIH-5031-001 Covered, filtered integrated circuit humidity sensor, SMD, 1000 units on tape and reel HIH-5030-001S Sample pack: covered integrated circuit humidity sensor, SMD, five units on tape HIH-5031-001S Sample pack: covered, filtered integrated circuit humidity sensor, SMD, sample pack, five units on tape ADDITIONAL HUMIDITY SENSOR INFORMATION See the following associated literature is available on the Web: Product installation instructions Application sheets: – Humidity Sensor Performance Characteristics – Humidity Sensor Theory and Behavior – Humidity Sensor Moisture and Psychrometrics – Thermoset Polymer-based Capacitive Sensors Honeywell Sensing and Control 7

WARNING WARNING MISUSE OF DOCUMENTATION PERSONAL INJURY The information presented in this product sheet is for DO NOT USE these products as safety or emergency stop reference only. Do not use this document as a product devices or in any other application where failure of the installation guide. product could result in personal injury. Complete installation, operation, and maintenance Failure to comply with these instructions could result information is provided in the instructions supplied with in death or serious injury. each product. Failure to comply with these instructions could result SALES AND SERVICE in death or serious injury. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For WARRANTY/REMEDY application assistance, current specifications, pricing or name Honeywell warrants goods of its manufacture as being free of of the nearest Authorized Distributor, contact your local sales defective materials and faulty workmanship. Honeywells office or: standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order E-mail: info.sc@honeywell.com acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell Internet: www.honeywell.com/sensing during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The Phone and Fax: foregoing is buyers sole remedy and is in lieu of all other Asia Pacific +65 6355-2828 warranties, expressed or implied, including those of +65 6445-3033 Fax merchantability and fitness for a particular purpose. In no Europe +44 (0) 1698 481481 event shall Honeywell be liable for consequential, special, +44 (0) 1698 481676 Fax or indirect damages. Latin America +1-305-805-8188 +1-305-883-8257 Fax While we provide application assistance personally, through USA/Canada +1-800-537-6945 our literature and the Honeywell web site, it is up to the +1-815-235-6847 customer to determine the suitability of the product in the +1-815-235-6545 Fax application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 009050-2-EN IL50 GLO Printed in USA Mar 2010 www.honeywell.com © 2010 Honeywell International Inc. All rights reserved.